An Evaluation of the Effect of Pulsed Ultrasound on the Cleaning Efficacy of Passive Ultrasonic Irrigation

Lei-Meng Jiang*, Bram Verhaagen, Michel Versluis, Chiara Zangrillo, Doris Cuckovic, Lucas W. M. van der Sluis

*Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    28 Citations (Scopus)

    Abstract

    Introduction: Multiple activations of the irrigant by using pulsed ultrasound may enhance the removal of dentin debris because of repeated acceleration of the irrigant. The aim of this study was to evaluate the effect of pulsed ultrasound on passive ultrasonic irrigation (PUI) in its ability to remove artificially placed dentin debris from a simulated apical oval extension within standardized root canals. Methods: Each of 20 in vitro root canal models with a standard groove in the apical portion of one canal wall filled with dentin debris received Phi repeatedly, either without pulsation (group1) or with pulsation (730 milliseconds on/100 milliseconds off in group 2, 400 milliseconds on/400 milliseconds off in group 3, and 100 milliseconds on/670 milliseconds off in group 4), corresponding to duty cycles of 100%, 88%, 50%, and 13%, respectively. After each irrigation procedure, the amount of dentin debris in the groove was evaluated by taking photographs of the groove and scoring. The irrigation procedures were also visualized in vitro using high-speed imaging performed in glass root canal models. Results: The debris score was significantly lower only in group 3 (p = 0.023). The in vitro visualization showed increased streaming and cavitation during the start-up phase of each pulse. Conclusions: PUI with a pulsation pattern of 400 milliseconds on/400 milliseconds off and a duty cycle of 50% is more effective in removing dentin debris from a simulated apical oval extension in standardized root canals than continuous ultrasonic activation. Duty cycles of 13% and 88% showed no difference compared with continuous oscillation. (J Endod 2010;36:1887-1891)

    Original languageEnglish
    Pages (from-to)1887-1891
    Number of pages5
    JournalJournal of endodontics
    Volume36
    Issue number11
    DOIs
    Publication statusPublished - Nov-2010

    Keywords

    • Dentin debris
    • passive ultrasonic irrigation
    • pulsation
    • pulsed ultrasound
    • ROOT CANALS
    • OVAL CANALS
    • HAND INSTRUMENTATION
    • FLOW-RATES
    • SONOLUMINESCENCE
    • REMOVE
    • SIZE
    • VIVO

    Fingerprint

    Dive into the research topics of 'An Evaluation of the Effect of Pulsed Ultrasound on the Cleaning Efficacy of Passive Ultrasonic Irrigation'. Together they form a unique fingerprint.

    Cite this