Biocompatibility of poly(D,L-lactic-co-hydroxymethyl glycolic acid) microspheres after subcutaneous and subcapsular renal injection

F. Kazazi-Hyseni, J. Zandstra, E. R. Popa, R. Goldschmeding, A. A. R. Lathuile, G. J. Veldhuis, C. F. Van Nostrum, W. E. Hennink, R. J. Kok*

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

13 Citations (Scopus)

Abstract

Poly(D,L-lactic-co-hydroxymethyl glycolic acid) (PLHMGA) is a biodegradable copolymer with potential as a novel carrier in polymeric drug delivery systems. In this study, the biocompatibility of PLHMGA microspheres (PLHMGA-ms) was investigated both in vitro in three different cell types (PK-84, HK-2 and PTECs) and in vivo at two implantation sites (by subcutaneous and subcapsular renal injection) in rats. Both monodisperse (narrow size distribution) and polydisperse PLHMGA-ms were prepared with volume weight mean diameter of 34 and 17 mu m, respectively. Mono and polydisperse PLHMGA-ms showed good cytocompatibility properties upon 72 h incubation with the cells (100 mu g microspheres/600 mu L/cell line). A mild foreign body reaction was seen shortly after subcutaneous injection (20 mg per pocket) of both mono and polydisperse PLHMGA-ms with the presence of mainly macrophages, few foreign body giant cells and myofibroblasts. This transient inflammatory reaction diminished within 28 days after injection, the time-point at which the microspheres were degraded. The degradation profile is comparable to the in vitro degradation time of the microspheres (i.e., within 35 days) when incubated at 37 degrees C in phosphate buffered saline. Subcapsular renal injection of monodisperse PLHMGA-ms (10 mg) in rats was characterized with similar inflammatory patterns compared to the subcutaneous injection. No cortical damage was observed in the injected kidneys. In conclusion, this study demonstrates that PLHMGA-ms are well tolerated after in vivo injection in rats. This makes them a good candidate for controlled delivery systems of low-molecular weight drugs as well as protein biopharmaceuticals. (C) 2014 Elsevier B.V. All rights reserved.

Original languageEnglish
Pages (from-to)99-109
Number of pages11
JournalInternational Journal of Pharmaceutics
Volume482
Issue number1-2
DOIs
Publication statusPublished - 30-Mar-2015

Keywords

  • PLHMGA
  • Cytocompatibility
  • Biocompatibility
  • Monodisperse microspheres
  • FUNCTIONALIZED POLY(ALPHA-HYDROXY ACID)S
  • IN-VITRO
  • PLGA MICROSPHERES
  • PROTEIN RELEASE
  • POLY(DL-LACTIDE-CO-GLYCOLIDE) MICROCAPSULES
  • POLYMER DEGRADATION
  • INVIVO DEGRADATION
  • DELIVERY-SYSTEMS
  • PARTICLE-SIZE
  • BIODEGRADATION

Fingerprint

Dive into the research topics of 'Biocompatibility of poly(D,L-lactic-co-hydroxymethyl glycolic acid) microspheres after subcutaneous and subcapsular renal injection'. Together they form a unique fingerprint.

Cite this