TY - JOUR
T1 - Clinical Validation of a Capillary Blood Home-Based Self-Sampling Technique for Monitoring of Infliximab, Vedolizumab, and C-Reactive Protein Concentrations in Patients With Inflammatory Bowel Disease
AU - Otten, Antonius T
AU - van der Meulen, Hedwig H
AU - Steenhuis, Maurice
AU - Loeff, Floris C
AU - Touw, Daan J
AU - Kosterink, Jos G W
AU - Frijlink, Henderik W
AU - Rispens, Theo
AU - Dijkstra, Gerard
AU - Visschedijk, Marijn C
AU - Bourgonje, Arno R
N1 - © 2023 Crohn’s & Colitis Foundation. Published by Oxford University Press on behalf of Crohn’s & Colitis Foundation.
PY - 2024/3
Y1 - 2024/3
N2 - BACKGROUND: Therapeutic drug monitoring provides important guidance for treatment of patients with inflammatory bowel disease (IBD) and could help to early identify treatment failure. This study aimed to validate a finger prick-based capillary blood sampling technique to measure biological trough levels and C-reactive protein (CRP) and evaluate patient performance and -support.METHODS: In this prospective cohort study, patients with IBD receiving infliximab (IFX) or vedolizumab (VEDO) therapy performed finger prick-based capillary blood sampling at home. Additionally, blood was collected through routinely performed in-hospital venepuncture prior to biological infusion. IFX, VEDO, and CRP concentrations were measured by enzyme-linked immunosorbent assay. The concordance between methods was statistically evaluated and a survey was conducted to assess practicality and patient support.RESULTS: In total, 81 patients (46 IFX, 35 VEDO) were enrolled. Mean differences between both methods were 0.42 (95% confidence interval, -1.74 to 2.58) μg/mL for IFX and 0.72 (95% confidence interval, -5.50 to 6.94) μg/mL for VEDO. Passing-Bablok regressions demonstrated no evidence for systematic or proportional biases. Venous and capillary IFX (ρ = 0.96, P < .001) and VEDO (ρ = 0.97, P < .001) levels strongly correlated and showed high intermethod agreement (Cohen's kappa: IFX = 0.82; VEDO = 0.94). Similarly, venous and capillary CRP levels were strongly correlated (ρ = 0.99, P < .001). Most patients (>95%) were able to successfully perform the self-sampling at home without prior instructions.CONCLUSIONS: This study clinically validated a finger prick-based capillary blood self-sampling technique allowing concomitant home monitoring of biological levels and CRP for patients with IBD, who reported substantial support, tolerability, and practicality.
AB - BACKGROUND: Therapeutic drug monitoring provides important guidance for treatment of patients with inflammatory bowel disease (IBD) and could help to early identify treatment failure. This study aimed to validate a finger prick-based capillary blood sampling technique to measure biological trough levels and C-reactive protein (CRP) and evaluate patient performance and -support.METHODS: In this prospective cohort study, patients with IBD receiving infliximab (IFX) or vedolizumab (VEDO) therapy performed finger prick-based capillary blood sampling at home. Additionally, blood was collected through routinely performed in-hospital venepuncture prior to biological infusion. IFX, VEDO, and CRP concentrations were measured by enzyme-linked immunosorbent assay. The concordance between methods was statistically evaluated and a survey was conducted to assess practicality and patient support.RESULTS: In total, 81 patients (46 IFX, 35 VEDO) were enrolled. Mean differences between both methods were 0.42 (95% confidence interval, -1.74 to 2.58) μg/mL for IFX and 0.72 (95% confidence interval, -5.50 to 6.94) μg/mL for VEDO. Passing-Bablok regressions demonstrated no evidence for systematic or proportional biases. Venous and capillary IFX (ρ = 0.96, P < .001) and VEDO (ρ = 0.97, P < .001) levels strongly correlated and showed high intermethod agreement (Cohen's kappa: IFX = 0.82; VEDO = 0.94). Similarly, venous and capillary CRP levels were strongly correlated (ρ = 0.99, P < .001). Most patients (>95%) were able to successfully perform the self-sampling at home without prior instructions.CONCLUSIONS: This study clinically validated a finger prick-based capillary blood self-sampling technique allowing concomitant home monitoring of biological levels and CRP for patients with IBD, who reported substantial support, tolerability, and practicality.