Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy

Adrian Thummerer*, Paolo Zaffino, Arturs Meijers, Gabriel G Marmitt, Joao Seco, Roel J H M Steenbakkers, Johannes A Langendijk, Stefan Both, Maria Francesca Spadea, Antje-Christin Knopf

*Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    107 Citations (Scopus)
    321 Downloads (Pure)

    Abstract

    In-room imaging is a prerequisite for adaptive proton therapy. The use of onboard cone-beam computed tomography (CBCT) imaging, which is routinely acquired for patient position verification, can enable daily dose reconstructions and plan adaptation decisions. Image quality deficiencies though, hamper dose calculation accuracy and make corrections of CBCTs a necessity. This study compared three methods to correct CBCTs and create synthetic CTs that are suitable for proton dose calculations. CBCTs, planning CTs and repeated CTs (rCT) from 33 H&N cancer patients were used to compare a deep convolutional neural network (DCNN), deformable image registration (DIR) and an analytical image-based correction method (AIC) for synthetic CT (sCT) generation. Image quality of sCTs was evaluated by comparison with a same-day rCT, using mean absolute error (MAE), mean error (ME), Dice similarity coefficient (DSC), structural non-uniformity (SNU) and signal/contrast-to-noise ratios (SNR/CNR) as metrics. Dosimetric accuracy was investigated in an intracranial setting by performing gamma analysis and calculating range shifts. Neural network-based sCTs resulted in the lowest MAE and ME (37/2 HU) and the highest DSC (0.96). While DIR and AIC generated images with a MAE of 44/77 HU, a ME of -8/1 HU and a DSC of 0.94/0.90. Gamma and range shift analysis showed almost no dosimetric difference between DCNN and DIR based sCTs. The lower image quality of AIC based sCTs affected dosimetric accuracy and resulted in lower pass ratios and higher range shifts. Patient-specific differences highlighted the advantages and disadvantages of each method. For the set of patients, the DCNN created synthetic CTs with the highest image quality. Accurate proton dose calculations were achieved by both DCNN and DIR based sCTs. The AIC method resulted in lower image quality and dose calculation accuracy was reduced compared to the other methods.

    Original languageEnglish
    Article number095002
    Number of pages17
    JournalPhysics in Medicine and Biology
    Volume65
    Issue number9
    Early online date27-Apr-2020
    DOIs
    Publication statusPublished - May-2020

    Keywords

    • adaptive proton therapy
    • CBCT
    • synthetic CT
    • neural networks
    • CONE-BEAM CT
    • IMAGE REGISTRATION
    • COMPUTED-TOMOGRAPHY
    • SHADING CORRECTION
    • RADIATION-THERAPY
    • HEAD
    • FEASIBILITY
    • RADIOTHERAPY
    • ARTIFACTS
    • TOOL

    Fingerprint

    Dive into the research topics of 'Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy'. Together they form a unique fingerprint.

    Cite this