Skip to main navigation Skip to search Skip to main content

COMPRESSIVE PROPERTIES OF TRABECULAR BONE RELATED TO MICROCT EVALUATED MORPHOMETRIC PARAMETERS: PRELIMINARY RESULTS

  • Egon Perilli*
  • , Massimiliano Baleani
  • , Wouter Raatjes
  • , Fabio Baruffaldi
  • , Angelo Cappello
  • , Aldo Toni
  • *Corresponding author for this work

    Research output: Contribution to journal › Article › Academic › peer-review

    Abstract

    This work describes the preliminary results of an ongoing study, that aims to obtain relationships between the experimentally determined mechanical properties of trabecular bone of the human femoral head and the morphometric parameters evaluated by microCT.

    Thirteen cylindrical samples of human trabecular bone were extracted from the femoral head of thirteen patients. They were examined by microCT and then mechanically tested in compression along the main axis observable in the trabeculae. After mechanical testing, the ash density of the samples was determined.

    Linear relationships were found between ash density and the bone volume fraction (R-2 = 0.83), elastic modulus and bone volume fraction (R-2 = 0.72), ultimate stress and bone volume fraction (R-2 = 0.81), in agreement with what reported in literature.

    The described protocol will be used to investigate trabecular bone samples collected from patients with different pathologies.

    Original languageEnglish
    Pages (from-to)349-355
    Number of pages7
    JournalJournal of mechanics in medicine and biology
    Volume5
    Issue number2
    DOIs
    Publication statusPublished - Jun-2005

    Keywords

    • Trabecular bone
    • bone mechanics
    • elastic modulus
    • bone architecture
    • micro-computed tomography
    • histomorphometry

    Fingerprint

    Dive into the research topics of 'COMPRESSIVE PROPERTIES OF TRABECULAR BONE RELATED TO MICROCT EVALUATED MORPHOMETRIC PARAMETERS: PRELIMINARY RESULTS'. Together they form a unique fingerprint.

    Cite this