Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories

  • CJPM Teirlinck*
  • , RA Bezemer
  • , C Kollmann
  • , J Lubbers
  • , PR Hoskins
  • , P Fish
  • , KE Fredfeldt
  • , UG Schaarschmidt
  • *Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    127 Citations (Scopus)

    Abstract

    Doppler test objects are used to characterise Doppler systems, both stand-alone systems and the Doppler part of so-called duplex scanners. The aim of the project partially presented here is the development and validation of an example of a Doppler test object fulfilling the requirements of the IEC 1685. The project has been carried out by nine partners of five European countries and has been funded by the European Commission.

    The flow Doppler test object is composed of: tissue mimicking material (TMM), blood mimicking fluid (BMF), tube (embedded in the TMM and carrying the BMF), tank, flow system, including a pump and a flow meter. In the normative part of the IEC 1685, requirements are given for the values of acoustical parameters of TMM and BMF such as sound velocity, attenuation and backscattering. For BMF, requirements are given also for values of density and viscosity. In an informative (but not compulsory) annex, a description is given of a flow test object meeting these requirements as an example.

    This 'example test object' developed during the project is composed of TMM based on agar and including SIC-and Al2O3-powders, BMF based on nylon particles suspended in water and glycerine, and a tube of c-flex, a silicon copolymer. Two tube sizes are used: 4.0 mm ID and 8.0 mm ID. During the project, very precise recipes have been developed for the composition and preparation of both TMM and BMF. Based on these recipes and a description of the construction in a design five flow test objects have been constructed in the laboratories of five participants.

    The test objects have been compared by measurements of the physical parameters and by Doppler measurements of the five test objects with the same Doppler system. The measurements have been carried out by five observers. Inter-test object and inter-observer variabilities are determined, yielding information about usefulness of the parameters. (C) 1998 Elsevier Science B.V.

    Original languageEnglish
    Pages (from-to)653-660
    Number of pages8
    JournalUltrasonics
    Volume36
    Issue number1-5
    Publication statusPublished - Feb-1998
    Event17th Ultrasonics International Conference (UI 97) - , Netherlands
    Duration: 2-Jul-19974-Jul-1997

    Keywords

    • flow Doppler test object
    • standardisation intercomparison
    • test object variability
    • observer variability

    Fingerprint

    Dive into the research topics of 'Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories'. Together they form a unique fingerprint.

    Cite this