Evaluating the benefit of PBS vs. VMAT dose distributions in terms of dosimetric sparing and robustness against inter-fraction anatomical changes for pediatric abdominal tumors

Filipa Guerreiro, Cornel Zachiu, Enrica Seravalli, Cássia O Ribeiro, Geert O Janssens, Mario Ries, Baudouin Denis de Senneville, John H Maduro, Charlotte L Brouwer, Erik W Korevaar, Antje C Knopf, Bas W Raaymakers

    Research output: Contribution to journalArticleAcademicpeer-review

    15 Citations (Scopus)
    245 Downloads (Pure)

    Abstract

    Background and purpose: To evaluate the dosimetric sparing and robustness against inter-fraction anatomical changes between photon and proton dose distributions for children with abdominal tumors.

    Material and methods: Volumetric modulated arc therapy (VMAT) and intensity-modulated pencil beam scanning (PBS) proton dose distributions were calculated for 20 abdominal pediatric cases (average 3, range 1-8 years). VMAT plans were based on a full-arc while PBS plans on 2-3 posterior-oblique irradiation fields. Plans were robustly optimized on a patient-specific internal target volume (ITV) using a uniform 5 mm set-up uncertainty. Additionally, for the PBS plans a +/- 3% proton range uncertainty was accounted for. Fractional dose re-calculations were performed using the planning computed tomography (CT) deformably registered to the daily cone-beam CT (CBCT) images. Fractional doses were accumulated rigidly. Planned and CBCT accumulated VMAT and PBS dose distributions were compared using dose-volume histogram (DVH) parameters.

    Results: Significant better sparing of the organs at risk with a maximum reduction in the mean dose of 40% was achieved with PBS. Mean ITV DVH parameters differences between planned and CBCT accumulated dose distributions were smaller than 0.5% for both VMAT and PBS. However, the ITV coverage (V-95% > 99%) was not reached for one patient for the accumulated VMAT dose distribution.

    Conclusions: For pediatric patients with abdominal tumors, improved dosimetric sparing was obtained with PBS compared to VMAT. In addition, PBS delivered by posterior-oblique irradiation fields demonstrated to be robust against anatomical inter-fraction changes. Compared to PBS, daily anatomical changes proved to affect the target coverage of VMAT dose distributions to a higher extent. (C) 2019 Elsevier B.V. All rights reserved.

    Original languageEnglish
    Pages (from-to)158-165
    Number of pages8
    JournalRadiotherapy and Oncology
    Volume138
    DOIs
    Publication statusPublished - Sept-2019

    Keywords

    • Pediatric IGRT
    • Pediatric abdominal tumors
    • Robust pencil beam scanning
    • Proton therapy
    • VMAT
    • Inter-fraction anatomical changes
    • MODULATED PROTON THERAPY
    • TREATMENT UNCERTAINTIES
    • WILMS-TUMOR
    • OPEN-LABEL
    • RADIOTHERAPY
    • OPTIMIZATION
    • PHOTON
    • CANCER
    • REGISTRATION
    • SENSITIVITY