Experimental and Modelling Studies of Mass Transfer in Centrifugal Contactors

Steve Drewery, Erik Heeres, Steve Percival, Chris Rhodes, Mitch St. George, Erwin Wilbers, David A. Woodhead

Research output: Contribution to journalArticleAcademic

453 Downloads (Pure)

Abstract

Experimental trials have been undertaken to determine interfacial area for mass transfer in 5cm and 25cm diameter annular centrifugal contactors. All trials used 30% TBP in Exxsol D80 diluent, with extraction of HNO3 being studied at varying flowrates and volumetric flow ratios. Droplet size was determined using a laser reflectance probe. Results from the 5 cm rig showed two different regions of operation and the value of the dimensionless constant (K) in the Kolmogoroff expression was estimated to be 0.28 for O/A ratios below 2.5 and 0.30 above 2.5. From the 25cm rig trials K was estimated to be 0.26.
Original languageEnglish
Pages (from-to)341-348
Number of pages8
JournalProcedia Chemistry
Volume7
Issue number11
DOIs
Publication statusPublished - 2012

Keywords

  • Solvent Extraction
  • Mass Transfer
  • Droplet Size
  • Area
  • Annular Centrifugal Contactor