Impact of coronal and sagittal views on lung gross tumor volume delineation

Isabelle Fitton, Joop C. Duppen, Roel J. H. M. Steenbakkers, Heidi Lotz, Peter J. C. M. Nowak, Coen R. N. Rasch, Marcel van Herk*

*Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    2 Citations (Scopus)

    Abstract

    Background and purpose: To study the impact of coronal and sagittal views (CSV) on the gross tumor volume (GTV) delineation on CT and matched PET/CT scans in non-small cell lung cancer.

    Material and methods: GTV delineations were performed by 11 experienced radiation oncologists on CT and PET/CT in 22 patients. Two tumor groups were defined: Group I: Primary tumors surrounded by lung or visceral pleura, without venous invasion, and without large extensions to the chest wall or the mediastinum. Group II: Tumors invading the hilar region, heart, large vessels, pericardium, and the mediastinum and/or associated with atelectasis. Tumor volumes and inter-observers variations (SD) were calculated and compared according to the use of axial view only (AW), axial/coronal/sagittal views (ACSW) and ACSW/PET (ACSWP).

    Results: CSV were not frequently used (57.4% out of 242 delineations on CT). For group I, ACSW didn't improve significantly mean GTVs. SDs were small on CT and on PET (SD = 0.3 cm). For group II, ACSW had 27-46% smaller observer variation (mean SD = 0.7 cm) than AW (mean SD = 1.1 cm). The smaller observer variation of ACSW users was associated with, on average, a 40% smaller delineated volume (p = 0.038). Mean GTV of ACSWP was 21% larger than mean GTV of ACSW on CT.

    Conclusions: For smaller lung tumors surrounded by healthy lung tissue the effect of multiple axis delineation is limited. However, application of coronal and sagittal windows is highly beneficial for delineation of more complex tumors, with atelectasis and/or pathological lymph nodes even if PET is used. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

    Original languageEnglish
    Pages (from-to)1082-1087
    Number of pages6
    JournalPhysica medica-European journal of medical physics
    Volume32
    Issue number9
    DOIs
    Publication statusPublished - Sept-2016

    Keywords

    • Coronal view
    • Sagittal view
    • Radiotherapy
    • Lung cancer
    • Target delineation
    • Inter-observer variability
    • COMPUTED-TOMOGRAPHY
    • OBSERVER VARIATION
    • CT-PET
    • CANCER
    • NODES
    • CHEST