Influence of background air on microbial contamination during simulated i.v.-admixture preparation

H. Van Doorne*, J. H. Bakker, R. F. Meevis, A. Marskamp

*Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    15 Citations (Scopus)

    Abstract

    The effect of the cleanliness of environmental air on the microbial contamination of a simulated i.v.-admixture during its preparation by aseptic transfer was studied under three conditions: (i) in a laminar air flow (LAF) bench situated in a class 1000 clean room, (ii) in an LAF bench in a microbiology laboratory and (iii) on a bench in an ordinary laboratory. Three thousand bottles were manually filled with 10 ml of a nutrient broth under each of the three conditions. The liquid was transferred by means of a syringe and a needle that pierced through the rubber closures of the bottles. The numbers of contaminated bottles under those three conditions were 1, 1 and 2, respectively. Background contamination had no demonstrable effect on the incidence of contamination, provided that preparation of the simulated i.v.-admixture solution was performed by skilled personnel in an LAF cabinet and air contact is avoided.

    Original languageEnglish
    Pages (from-to)181-187
    Number of pages7
    JournalJournal of Clinical Pharmacy and Therapeutics
    Volume19
    Issue number3
    DOIs
    Publication statusPublished - Jun-1994