Inter-observer variation of hippocampus delineation in hippocampal avoidance prophylactic cranial irradiation

  • F. Bartel
  • , M. van Herk
  • , H. Vrenken
  • , F. Vandaele
  • , S. Sunaert
  • , K. de Jaeger
  • , N. J. Dollekamp
  • , C. Carbaat
  • , E. Lamers
  • , E. M. T. Dieleman
  • , Y. Lievens
  • , D. de Ruysscher
  • , S. B. Schagen
  • , M. B. de Ruiter
  • , J. C. de Munck
  • , J. Belderbos*
  • *Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    17 Citations (Scopus)
    120 Downloads (Pure)

    Abstract

    BackgroundHippocampal avoidance prophylactic cranial irradiation (HA-PCI) techniques have been developed to reduce radiation damage to the hippocampus. An inter-observer hippocampus delineation analysis was performed and the influence of the delineation variability on dose to the hippocampus was studied.Materials and methodsFor five patients, seven observers delineated both hippocampi on brain MRI. The intra-class correlation (ICC) with absolute agreement and the generalized conformity index (CIgen) were computed. Median surfaces over all observers' delineations were created for each patient and regional outlining differences were analysed. HA-PCI dose plans were made from the median surfaces and we investigated whether dose constraints in the hippocampus could be met for all delineations.ResultsThe ICC for the left and right hippocampus was 0.56 and 0.69, respectively, while the CIgen ranged from 0.55 to 0.70. The posterior and anterior-medial hippocampal regions had most variation with SDs ranging from approximately 1 to 2.5mm. The mean dose (D-mean) constraint was met for all delineations, but for the dose received by 1% of the hippocampal volume (D-1%) violations were observed.ConclusionThe relatively low ICC and CIgen indicate that delineation variability among observers for both left and right hippocampus was large. The posterior and anterior-medial border have the largest delineation inaccuracy. The hippocampus D-mean constraint was not violated.

    Original languageEnglish
    Pages (from-to)178-186
    Number of pages9
    JournalClinical & translational oncology
    Volume21
    Issue number2
    DOIs
    Publication statusPublished - Feb-2019

    Keywords

    • SCLC
    • HA-PCI
    • Hippocampus delineation
    • Inter-observer variation
    • CELL LUNG-CANCER
    • QUALITY-OF-LIFE
    • WHOLE-BRAIN RADIOTHERAPY
    • MANUAL SEGMENTATION
    • AUTOMATIC SEGMENTATION
    • ALZHEIMERS-DISEASE
    • RTOG 0212
    • RADIATION
    • METASTASES
    • TRIAL

    Fingerprint

    Dive into the research topics of 'Inter-observer variation of hippocampus delineation in hippocampal avoidance prophylactic cranial irradiation'. Together they form a unique fingerprint.

    Cite this