Abstract
Purpose: To evaluate long-term outcome of GORE EXCLUDER AAA Endoprosthesis (W.L. Gore & Associates, Inc, Flagstaff, Arizona) for elective treatment of infrarenal aortic aneurysms and to evaluate performance of different generations of the device.
Materials and Methods: A retrospective analysis was performed of 248 patients undergoing elective endovascular aneurysm repair with the GORE EXCLUDER between January 2000 and December 2015 in 2 hospitals. Primary endpoint was reintervention-free survival. Secondary endpoints were technical success, overall survival, rupture-free survival, endoleaks, sac diameter change (> 5 mm), limb occlusion, and migration (> 5 mm). Median follow-up time was 26 months (range, 1-190 months).
Results: Assisted primary technical success was 96.8%. Reintervention-free survival for 5 and 10 years was 85.2% and 75.6%, respectively. Independent risk factors for reintervention were technical success (P <.001), type I endoleak (P <.001), and type II endoleak (P = .003). Late adverse events requiring reintervention included rupture (0.4%), limb occlusion (0.4%), and stent migration (0.4%). Type Ia (4.8%), lb (2.8%), II (35.9%), and V (6.5%) endoleaks were reported throughout follow-up. Sac growth was more prevalent with the original GORE EXCLUDER compared with the low permeability GORE EXCLUDER (P = .001) and in the presence of type I, II, and V endoleaks (P
Conclusions: Treatment with the GORE EXCLUDER is effective with acceptable reintervention rates in the long-term and few device-related adverse events or ruptures up to 10 years. Observed late adverse events and new-onset endoleaks emphasize the need for long-term surveillance.
| Original language | English |
|---|---|
| Pages (from-to) | 637-644 |
| Number of pages | 8 |
| Journal | Journal of Vascular and Interventional Radiology |
| Volume | 28 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - May-2017 |
Keywords
- SINGLE-CENTER EXPERIENCE
- ENDOVASCULAR REPAIR
- STENT-GRAFT
- REGISTRY
- EUROSTAR
- RUPTURE
Fingerprint
Dive into the research topics of 'Long-Term Outcome of the GORE EXCLUDER AAA Endoprosthesis for Treatment of Infrarenal Aortic Aneurysms'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver