Patient-Specific Computational Model and Dosimetry Calculations for PET/CT of a Patient Pregnant with Twins

  • Tianwu Xie
  • , Paolo Zanotti-Fregonara
  • , Agathe Edet-Sanson
  • , Habib Zaidi*
  • *Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    14 Citations (Scopus)

    Abstract

    The radiation dose delivered to pregnant patients during radiologic imaging procedures raises health concerns because the developing embryo and fetus are considered to be highly radiosensitive. To appropriately weigh the diagnostic benefits against the radiation risks, the radiologist needs reasonably accurate and detailed estimates of the fetal dose. Expanding our previously developed series of computational phantoms for pregnant women, we here describe a personalized model for twin pregnancy, based on an actual clinical scan. Methods: The model is based on a standardized hybrid pregnant female and fetus phantom and on a clinical case of a patient who underwent an F-18-FDG PET/CT scan while expecting twins at 25 weeks' gestation. This model enabled us to produce a realistic physical representation of the pregnant patient and to estimate the maternal and fetal organ doses from the F-18-FDG and CT components. The Monte Carlo N-Particle Extended general-purpose code was used for radiation transport simulation. Results: The F-18-FDG doses for the 2 fetuses were 3.78 and 3.99 mGy, and the CT doses were 0.76 and 0.70 mGy, respectively. Therefore, the relative contribution of F-18-FDG and CT to the total dose to the fetuses was about 84% and 16%, respectively. Mean-while, for F-18-FDG, the calculated personalized absorbed dose was about 40%-50% higher than the doses reported by other dosimetry computer software tools. Conclusion: Our approach to constructing personalized computational models allows estimation of a patient- specific radiation dose, even in cases with unusual anatomic features such as a twin pregnancy. Our results also show that, even in twins, the fetal organ doses from both F-18-FDG and CT present a certain variability linked to the anatomic characteristics. The CT fetal dose is smaller than the F-18-FDG PET dose.

    Original languageEnglish
    Pages (from-to)1451-1458
    Number of pages8
    JournalJournal of Nuclear Medicine
    Volume59
    Issue number9
    DOIs
    Publication statusPublished - 1-Sept-2018

    Keywords

    • CT
    • radiation dosimetry
    • fetus
    • pregnant female models
    • Monte Carlo simulation
    • MONTE-CARLO SIMULATIONS
    • RADIATION-EXPOSURE
    • MULTIDETECTOR CT
    • NUCLEAR-MEDICINE
    • VOXEL PHANTOMS
    • CONCEPTUS
    • SCANNERS
    • FEMALE
    • FETUS
    • STANDARDIZATION

    Fingerprint

    Dive into the research topics of 'Patient-Specific Computational Model and Dosimetry Calculations for PET/CT of a Patient Pregnant with Twins'. Together they form a unique fingerprint.

    Cite this