Petra Trnková*, Alexandru Dasu, Lorenzo Placidi, Markus Stock, Iuliana Toma-Dasu, Charlotte L. Brouwer, Andrew Gosling, Emmanuel Jouglar, Ingrid Kristensen, Valentine Martin, Syed Moinuddin, Isabelle Pasquie, Sarah Peters, Alessia Pica, Sandija Plaude, Roberto Righetto, Barbara Rombi, Juliette Thariat, Hiske van der Weide, Aswin HoffmannAlessandra Bolsi

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

22 Downloads (Pure)

Abstract

Purpose: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI).
Methods: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process.
Results: Eleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow.
Conclusion: There were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.

Original languageEnglish
Article number103407
Number of pages9
JournalPhysica Medica
Volume123
DOIs
Publication statusPublished - Jul-2024

Keywords

  • Cranio-spinal axis
  • Image guided proton therapy
  • Immobilization
  • Positioning
  • Proton therapy

Fingerprint