TY - JOUR
T1 - SARS-CoV-2 antigen tests for screening of healthcare workers
T2 - experience with over 48,000 combined antigen tests and RT-PCR tests
AU - Piek, A
AU - Knoester, M
AU - Gard, L
AU - Lokate, M
AU - Niesters, H G M
AU - van Leer-Buter, C L
N1 - Funding Information:
We would like to thank all technicians of the molecular section of the department of Medical Microbiology and Infection Control of the UMCG for excellent technical assistance.
Publisher Copyright:
© 2022
PY - 2023/1
Y1 - 2023/1
N2 - BACKGROUND: To prevent spread to patients and co-workers, health care workers (HCWs) infected with Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) should quickly be identified. Although real time polymerase chain reaction (RT-PCR) is the gold standard, this test takes several hours, during which a HCW is unable to work. Antigen (Ag) tests may be an efficacious means of screening HCWs since they are easy to perform and provide fast results.METHODS: In this study, 48,010 paired results of Ag-testing and RT-PCR, performed on HCWs between January 2021 and April 2022, were evaluated to determine the diagnostic accuracy of SARS-CoV-2 Ag-tests in diagnosing potentially infectious individuals. This analysis was performed with cycling threshold values (Ct-values) ≤30 and ≤25 as cut-offs.RESULTS: Respectively 3.1% (n = 1507) and 0.3% (n = 140) of Ag-tests were positive or indeterminate, and thus indicative for SARS-CoV-2 infection. In total, 2479 (5.2%) RT-PCRs were positive, of which 1529 (61.7%) had a Ct-value ≤25 and 402 (16.2%) a Ct-value between 26 and 30. At Ct-value ≤30 as a cut-off, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Ag-tests were 79.0%, 99.8%, 93.8% and 99.1%, respectively. At Ct-value ≤25, sensitivity further improved to 92.0%, by which the NPV increased to 99.7%.CONCLUSIONS: To prevent transmission from HCWs to patients and co-workers, while maintaining workforce capacity, Ag-tests are a valuable addition to RT-PCR tests, as they have a quick turnaround time and excellent sensitivity for identifying individuals with high potential for transmission.
AB - BACKGROUND: To prevent spread to patients and co-workers, health care workers (HCWs) infected with Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) should quickly be identified. Although real time polymerase chain reaction (RT-PCR) is the gold standard, this test takes several hours, during which a HCW is unable to work. Antigen (Ag) tests may be an efficacious means of screening HCWs since they are easy to perform and provide fast results.METHODS: In this study, 48,010 paired results of Ag-testing and RT-PCR, performed on HCWs between January 2021 and April 2022, were evaluated to determine the diagnostic accuracy of SARS-CoV-2 Ag-tests in diagnosing potentially infectious individuals. This analysis was performed with cycling threshold values (Ct-values) ≤30 and ≤25 as cut-offs.RESULTS: Respectively 3.1% (n = 1507) and 0.3% (n = 140) of Ag-tests were positive or indeterminate, and thus indicative for SARS-CoV-2 infection. In total, 2479 (5.2%) RT-PCRs were positive, of which 1529 (61.7%) had a Ct-value ≤25 and 402 (16.2%) a Ct-value between 26 and 30. At Ct-value ≤30 as a cut-off, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Ag-tests were 79.0%, 99.8%, 93.8% and 99.1%, respectively. At Ct-value ≤25, sensitivity further improved to 92.0%, by which the NPV increased to 99.7%.CONCLUSIONS: To prevent transmission from HCWs to patients and co-workers, while maintaining workforce capacity, Ag-tests are a valuable addition to RT-PCR tests, as they have a quick turnaround time and excellent sensitivity for identifying individuals with high potential for transmission.
KW - Antigen test
KW - Health care worker
KW - Hospital management
KW - Infection prevention
KW - Real-time polymerase chain reaction
KW - SARS-CoV-2
U2 - 10.1016/j.jcv.2022.105326
DO - 10.1016/j.jcv.2022.105326
M3 - Article
C2 - 36403314
SN - 1386-6532
VL - 158
JO - Journal of Clinical Virology
JF - Journal of Clinical Virology
M1 - 105326
ER -