Abstract

In this paper, augmentation has been applied to data matrices, which originate from hyphenated methods that share the same mode of detection, but use different separation methods, HPLC-DAD and MEKC-DAD. A novel method, wavelength shift eigenstructure tracking (WET), has been proposed for the alignment between the wavelength scale of both detectors. WET proves to be suitable for the detection as well as correction of wavelength shift between both detectors. After correction of the wavelength scale, data obtained on both systems have been augmented and submitted to iterative target transformation factor analysis. Augmented curve resolution provides significantly better estimates of the chromatographic and electrophoretic profiles and spectra than the use of non-augmented curve resolution on HPLC and MEKC data separately. It is particularly useful when the pure fraction of a chromatographic peak is less than 0.10. Finally, the relative weight of MEKC versus HPLC in augmentation may be increased using intensity and noise normalisation. However, since noise normalisation and its accompanying decrease in signal-to-noise ratio leads to a loss of information, and, since intensity normalisation may cause a failure of the augmented curve resolution algorithm, benefits and drawbacks of normalisation should be weighed on a case-by-case basis. (c) 2005 Elsevier B.V. All rights reserved.

Original languageEnglish
Pages (from-to)165-176
Number of pages12
JournalJournal of Chromatography.A.
Volume1096
Issue number1-2
DOIs
Publication statusPublished - 25-Nov-2005

Keywords

  • high performance liquid chromatography
  • micellar electrokinetic chromatography
  • diode array detection
  • iterative target transformation factor analysis
  • augmentation
  • wavelength shift eigenstructure tracking
  • MULTIVARIATE CURVE RESOLUTION
  • PIECEWISE DIRECT STANDARDIZATION
  • ORTHOGONAL PROJECTION APPROACH
  • NEAR-INFRARED SPECTROSCOPY
  • ALTERNATING LEAST-SQUARES
  • CALIBRATION TRANSFER
  • SPECTROPHOTOMETRIC TITRATIONS
  • INSTRUMENT STANDARDIZATION
  • FLUORESCENCE SPECTROSCOPY
  • ACID-BASE

Fingerprint

Dive into the research topics of 'Simultaneous resolution of overlapping peaks in high-performance liquid chromatography and micellar electrokinetic chromatography with diode array detection using augmented iterative target transformation factor analysis'. Together they form a unique fingerprint.

Cite this