The new readout electronics for the BaF2-calorimeter TAPS

P Drexler*, U Thoring, W Bonn, HAP van der Duin, R Holzmann, G van der Kruk, B Krusche, H Lohner, V Metag, TW Nijboer, R Novotny, A Potapov, C Salz, S Schadmand, M Steinacher, M Thiel, H Vorenholt

*Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    8 Citations (Scopus)

    Abstract

    A highly compact and fast VME based readout board for BaF2 scintillation detectors has been designed, developed, and finally tested in an in-beam experiment. Adapted to the excellent properties of BaF2, the unit allows to digitize time, energy, and pulse-shape information of four detector channels in parallel. The board is piggy-back plugged onto a motherboard containing a high-speed 12-bit ADC and the VME interface, commercially available in the customized version CAEN V874 A. Both combine to one single VME slot. A first measurement of the photon response of a TAPS subarray with energy tagged photons up to 2.6 GeV documents the full functionality and excellent performance.

    Original languageEnglish
    Pages (from-to)969-973
    Number of pages5
    JournalIEEE Transactions on Nuclear Science
    Volume50
    Issue number4
    DOIs
    Publication statusPublished - Aug-2003
    EventNuclear Science Symposium (NSS)/Symposium on Nuclear Power Systems (SNPS) -
    Duration: 10-Nov-200216-Nov-2002

    Keywords

    • analog circuits
    • analog-to-digital conversion (ADC)
    • BaF2
    • calorimetry
    • gamma-ray detectors
    • measurement
    • scintillators
    • timing circuits
    • PHOTON SPECTROMETER TAPS
    • VME BOARD
    • DETECTOR

    Cite this