The relationship between applied energy and ablation zone volume in patients with hepatocellular carcinoma and colorectal liver metastasis

Wouter J. Heerink*, A. Millad Solouki, Rozemarijn Vliegenthart, Simeon J. S. Ruiter, Egbert Sieders, Matthijs Oudkerk, Koert P. de Jong

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

30 Citations (Scopus)
258 Downloads (Pure)

Abstract

To study the ratio of ablation zone volume to applied energy in computed tomography (CT)-guided radiofrequency ablation (RFA) and microwave ablation (MWA) in patients with hepatocellular carcinoma (HCC) in a cirrhotic liver and in patients with colorectal liver metastasis (CRLM).

In total, 90 liver tumors, 45 HCCs in a cirrhotic liver and 45 CRLMs were treated with RFA or with one of two MWA devices (MWA_A and MWA_B), resulting in 15 procedures for each tumor type, per device. Device settings were recorded and the applied energy was calculated. Ablation volumes were segmented on the contrast-enhanced CT scans obtained 1 week after the procedure. The ratio of ablation zone volume in milliliters to applied energy in kilojoules was determined for each procedure and compared between HCC (R (HCC)) and CRLM (R (CRLM)), stratified according to ablation device.

With RFA, R (HCC) and R (CRLM) were 0.22 mL/kJ (0.14-0.45 mL/kJ) and 0.15 mL/kJ (0.14-0.22 mL/kJ; p = 0.110), respectively. With MWA_A, R (HCC) was 0.81 (0.61-1.07 mL/kJ) and R (CRLM) was 0.43 (0.35-0.61 mL/kJ; p = 0.001). With MWA_B, R (HCC) was 0.67 (0.41-0.85 mL/kJ) and R (CRLM) was 0.43 (0.35-0.61 mL/kJ; p = 0.040).

With RFA, there was no significant difference in energy deposition ratio between tumor types. With both MWA devices, the ratios were higher for HCCs. Tailoring microwave ablation device protocols to tumor type might prevent incomplete ablations.

aEuro cent HCCs and CRLMs respond differently to microwave ablation

aEuro cent For MWA, CRLMs required more energy to achieve a similar ablation volume

aEuro cent Tailoring ablation protocols to tumor type might prevent incomplete ablations.

Original languageEnglish
Pages (from-to)3228-3236
Number of pages9
JournalEuropean Radiology
Volume28
Issue number8
Early online date13-Mar-2018
DOIs
Publication statusPublished - Aug-2018

Keywords

  • Ablation techniques
  • Carcinoma, Hepatocellular
  • Radiology, Interventional
  • Multidetector computed tomography
  • Liver diseases
  • MICROWAVE THERMOSPHERE ABLATION
  • RADIOFREQUENCY ABLATION
  • RISK-FACTORS
  • PROGNOSTIC-FACTORS
  • TUMORS
  • RECURRENCE
  • SEVERITY
  • DISEASE

Cite this