N2 - Background: Both global ischemia caused by circulatory arrest and extracorporeal circulation circuits have been shown to trigger cytokine release. We hypothesized that inserting a hemoadsorption device during thoraco-abdominal normothermic regional perfusion (TA-NRP) in the donation after circulatory death setting would mitigate the inflammatory response, potentially resulting in improved cardiac allograft function. Methods: In 15 pigs, circulatory arrest was induced by hypoxia. After a 15-min no-touch-period, TA-NRP was performed for 60 min. Eight pigs had a hemoadsorption device incorporated in the ECC, while seven did not. Plasma concentrations of IFN-α, IFN-γ, TNF-α, IL-1β, IL-4, IL-6, IL-8, IL-10, and IL-12p40 were assessed by ELISA at baseline, immediately at start of TA-NRP, 60 min after start of TA-NRP (just before weaning from ECC), and at 30 and 60 min after weaning from ECC. Cardiac function was assessed with pressure–volume loop analysis. Results: Hemoadsorption had no relevant effects on systemic cytokine levels post TA-NRP. IL-6 plasma levels gradually rose throughout the procedure for both groups. Hemoadsorption did not affect systolic or diastolic left ventricular function, nor were global hemodynamics improved by hemoadsorption. Conclusions: The insertion of a hemoadsorption device did not significantly affect plasma cytokine levels or cardiac function. Further research is necessary to assess the role of the inflammatory response in DCD heart transplantation and its modulation by TA-NRP.
AB - Background: Both global ischemia caused by circulatory arrest and extracorporeal circulation circuits have been shown to trigger cytokine release. We hypothesized that inserting a hemoadsorption device during thoraco-abdominal normothermic regional perfusion (TA-NRP) in the donation after circulatory death setting would mitigate the inflammatory response, potentially resulting in improved cardiac allograft function. Methods: In 15 pigs, circulatory arrest was induced by hypoxia. After a 15-min no-touch-period, TA-NRP was performed for 60 min. Eight pigs had a hemoadsorption device incorporated in the ECC, while seven did not. Plasma concentrations of IFN-α, IFN-γ, TNF-α, IL-1β, IL-4, IL-6, IL-8, IL-10, and IL-12p40 were assessed by ELISA at baseline, immediately at start of TA-NRP, 60 min after start of TA-NRP (just before weaning from ECC), and at 30 and 60 min after weaning from ECC. Cardiac function was assessed with pressure–volume loop analysis. Results: Hemoadsorption had no relevant effects on systemic cytokine levels post TA-NRP. IL-6 plasma levels gradually rose throughout the procedure for both groups. Hemoadsorption did not affect systolic or diastolic left ventricular function, nor were global hemodynamics improved by hemoadsorption. Conclusions: The insertion of a hemoadsorption device did not significantly affect plasma cytokine levels or cardiac function. Further research is necessary to assess the role of the inflammatory response in DCD heart transplantation and its modulation by TA-NRP.
KW - cytokines
KW - donation after circulatory death
KW - heart transplantation
KW - hemoadsorption
KW - porcine
KW - thoraco-abdominal normothermic regional perfusion