title = "A bistable microfluidic phase change actuator and optimization of its response times",
abstract = "In this paper we present a robust, bistable microfluidic phase change (PC) actuator for microfluidic valves and pumps that can be operated using a highly integrated platform for individual control of up to 588 thermally driven actuators. Furthermore we investigated the correlation between the response times of the actuator and heating power of different resistors as well as the impact of the phase change material (PCM) volume on this correlation.",
keywords = "Bistable actuator, Microfluidic, Phase change",
author = "C. Neumann and E. Wilhelm and A. Voigt and Rapp, {B. E.}",
note = "Publisher Copyright: {\textcopyright} 14CBMS.; 18th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2014 ; Conference date: 26-10-2014 Through 30-10-2014",
year = "2014",
language = "English",
series = "18th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2014",
publisher = "Chemical and Biological Microsystems Society ",
pages = "2202--2204",
booktitle = "18th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2014",
}