A status report of the KVI-AECR

H. R. Kremers*, J. P. M. Beijers, S. Brandenburg, J. Mulder

*Bijbehorende auteur voor dit werk

OnderzoeksoutputAcademicpeer review

Samenvatting

In this paper the first results of the new ECR source at the KVI axe presented. The source has been built following the design of Jyvaskyla University, which is based on the AECR-U of LBNL. As the commissioning is going on, it seems that the extraction and analysing systems inherited from the old source are the limiting factors for the performance of the new source. Beam currents achieved with the source are at the moment a factor of 3 lower than the AECR source used at the Jyvaskyla University. Further modifications to improve the source performance will be discussed.

Originele taal-2English
Pagina's (van-tot)90-93
Aantal pagina's4
TijdschriftHigh energy physics and nuclear physics-Chinese edition
Volume31
StatusPublished - jul-2007
Evenement17th International Workshop on ECR Ion Sources and Their Applications -
Duur: 17-sep-200621-sep-2006

Citeer dit