TY - JOUR
T1 - Agreement of somatic and renal near-infrared spectroscopy with reference blood samples during a controlled hypoxia sequence
T2 - a healthy volunteer study
AU - De Keijzer, Ilonka N.
AU - Massari, Dario
AU - Niezen, Caren K.
AU - Bokkers, Reinoud P.H.
AU - Vos, Jaap Jan
AU - Scheeren, Thomas W.L.
N1 - Funding Information:
This study was sponsored by Masimo Corporation, Irvine, California, USA. The sponsor provided study equipment and financial support, but had no role in the data analysis or preparation of this manuscript.
Publisher Copyright:
© 2022, The Author(s).
PY - 2023
Y1 - 2023
N2 - PURPOSE: O3® Regional Oximetry (Masimo Corporation, California, USA) is validated for cerebral oximetry. We aimed to assess agreement of somatic and renal near-infrared spectroscopy with reference blood samples.METHODS: O3 sensors were placed bilaterally on the quadriceps and flank of 26 healthy volunteers. A stepped, controlled hypoxia sequence was performed by adding a mixture of nitrogen and room air to the breathing circuit. O3-derived oxygen saturation values were obtained at baseline and at six decremental saturation levels (5% steps). Blood samples (radial artery, iliac vein (somatic reference) and renal vein) were obtained at each step. Reference values were calculated as: 0.7 × venous saturation + 0.3 × arterial saturation. The agreement between O3-derived values with blood reference values was assessed by calculating root-mean-square error accuracy and Bland-Altman plots.RESULTS: The root-mean-square error accuracy was 6.0% between quadriceps oxygen saturation and somatic reference values. The mean bias was 0.8%, with limits of agreement from -7.7 to 9.3%. These were 5.1% and 0.6% (-8.3 to 9.5%) for flank oxygen saturation and somatic reference values, respectively, and 7.7% and -4.9% (-15.0 to 5.2%) for flank oxygen saturation and renal reference values. The kidney depth was 3.1 ± 0.9 cm below the skin.CONCLUSION: O3 regional oximetry can be used on the quadriceps and flank to monitor somatic saturation, yet has a saturation-level dependent bias. O3-derived values obtained at the flank underestimated renal reference values. Additionally, it is unlikely that the flank sensors did directly measure renal tissue.TRIAL REGISTRATION: Clinicaltrials.gov (NCT04584788): registered October 6th, 2020.
AB - PURPOSE: O3® Regional Oximetry (Masimo Corporation, California, USA) is validated for cerebral oximetry. We aimed to assess agreement of somatic and renal near-infrared spectroscopy with reference blood samples.METHODS: O3 sensors were placed bilaterally on the quadriceps and flank of 26 healthy volunteers. A stepped, controlled hypoxia sequence was performed by adding a mixture of nitrogen and room air to the breathing circuit. O3-derived oxygen saturation values were obtained at baseline and at six decremental saturation levels (5% steps). Blood samples (radial artery, iliac vein (somatic reference) and renal vein) were obtained at each step. Reference values were calculated as: 0.7 × venous saturation + 0.3 × arterial saturation. The agreement between O3-derived values with blood reference values was assessed by calculating root-mean-square error accuracy and Bland-Altman plots.RESULTS: The root-mean-square error accuracy was 6.0% between quadriceps oxygen saturation and somatic reference values. The mean bias was 0.8%, with limits of agreement from -7.7 to 9.3%. These were 5.1% and 0.6% (-8.3 to 9.5%) for flank oxygen saturation and somatic reference values, respectively, and 7.7% and -4.9% (-15.0 to 5.2%) for flank oxygen saturation and renal reference values. The kidney depth was 3.1 ± 0.9 cm below the skin.CONCLUSION: O3 regional oximetry can be used on the quadriceps and flank to monitor somatic saturation, yet has a saturation-level dependent bias. O3-derived values obtained at the flank underestimated renal reference values. Additionally, it is unlikely that the flank sensors did directly measure renal tissue.TRIAL REGISTRATION: Clinicaltrials.gov (NCT04584788): registered October 6th, 2020.
KW - NIRS
KW - Regional oximetry
KW - Renal oxygen saturation
KW - Somatic oxygen saturation
KW - Tissue oxygenation
U2 - 10.1007/s10877-022-00944-9
DO - 10.1007/s10877-022-00944-9
M3 - Article
C2 - 36463540
AN - SCOPUS:85143282416
SN - 1387-1307
VL - 37
SP - 805
EP - 814
JO - Journal of Clinical Monitoring and Computing
JF - Journal of Clinical Monitoring and Computing
ER -