This study was performed because of observed differences between dye dilution cardiac output and the Fick cardiac output, calculated from estimated oxygen consumption according to LaFarge and Miettinen, and to find a better formula for assumed oxygen consumption. In 250 patients who underwent left and right heart catheterization, the oxygen consumption VO2 (ml.min(-1)) was calculated using Ficks principle. Either pulmonary or systemic flow, as measured by dye dilution, was used in combination with the concordant arteriovenous oxygen concentration difference. In 130 patients, who matched the age of the LaFarge and miettinen population, the obtained values of oxygen consumption VO2(dd) were compared with the estimated oxygen consumption values VO2(lfm), found using the LaFarge and Miettinen formulae. The VO2(lfm) was significantly lower than VO2(dd); -21.8 +/- 29.3 ml.min(-1) (mean +/- SD), P

VO2(ass)=(157.3 x BSA + 10.0 x Sex-10.5 x ln Age + $.*) ml.min(-1), where ln Age=the natural logarithm of the age. This formula was validated prospectively in 60 patients. A non-significant difference between VO2(ass) and VO2(dd) was found; mean 2.0 +/- 23.4 ml.min(-1). P=0.771, 95% Cl=-4.0 to +8.0, LA -44.7 to +48.7. In conclusion, assumed oxygen consumption values, using our new formula, are in better agreement with the actual values than those found according to LaFarge and Miettien's formulae.

Originele taal-2English
Pagina's (van-tot)698-703
Aantal pagina's6
TijdschriftEuropean Heart Journal
Volume16
Nummer van het tijdschrift5
StatusPublished - mei-1995

Citeer dit