TY - JOUR
T1 - Congruent identification of imbalanced fibrinolysis by 2 distinct clot lysis time assays
AU - Driever, Ellen G.
AU - Larsen, Julie Brogaard
AU - Bos, Sarah
AU - Bernal, William
AU - Hvas, Anne Mette
AU - Lisman, Ton
N1 - Funding Information:
Funding information This study was funded in part by a grant from the Dutch Thrombosis Foundation (2018-02).
Publisher Copyright:
© 2023 The Author(s)
PY - 2023/1
Y1 - 2023/1
N2 - Background: A plasma-based clot lysis time (CLT) assay is an established research test to assess plasma fibrinolytic potential, with application in hyperfibrinolytic or hypofibrinolytic conditions. Interprotocol variations make comparisons between laboratories challenging. The aim of this study was to compare the results of 2 different CLT assays performed by 2 distinct research laboratories by using their own protocol. Methods: We evaluated fibrinolysis in the plasma of 60 patients undergoing hepatobiliary surgery and in plasma from a healthy donor that was spiked with commonly used anticoagulant drugs (enoxaparin, dabigatran, and rivaroxaban) in 2 distinct laboratories (Aarhus and Groningen) by using 2 different assays that differ, among others, in tissue plasminogen activator (tPA) concentration. Results: Overall conclusions on fibrinolytic potential in patients undergoing hepatobiliary surgery were similar between the 2 CLT assays, with hyperfibrinolytic and hypofibrinolytic profiles identified at the same time points during and after surgery. Severe hypofibrinolysis was less commonly reported in the Aarhus assay (36/319 samples; 11%) than in the Groningen assay (55/319 samples; 17%). No clot formation was observed in 31 of 319 samples in the Aarhus assay vs 0 of 319 samples in the Groningen assay. Clotting times increased much more profoundly on the addition of all 3 anticoagulants in the Aarhus assay. Conclusions: Despite the differences in laboratory, protocol, reagents, operator, data processing, and analysis, overall conclusions on fibrinolytic capacity are similar between the 2 laboratories. With a higher concentration of tPA in the Aarhus assay, the test becomes less sensitive for the detection of hypofibrinolysis and is more sensitive to the addition of anticoagulants.
AB - Background: A plasma-based clot lysis time (CLT) assay is an established research test to assess plasma fibrinolytic potential, with application in hyperfibrinolytic or hypofibrinolytic conditions. Interprotocol variations make comparisons between laboratories challenging. The aim of this study was to compare the results of 2 different CLT assays performed by 2 distinct research laboratories by using their own protocol. Methods: We evaluated fibrinolysis in the plasma of 60 patients undergoing hepatobiliary surgery and in plasma from a healthy donor that was spiked with commonly used anticoagulant drugs (enoxaparin, dabigatran, and rivaroxaban) in 2 distinct laboratories (Aarhus and Groningen) by using 2 different assays that differ, among others, in tissue plasminogen activator (tPA) concentration. Results: Overall conclusions on fibrinolytic potential in patients undergoing hepatobiliary surgery were similar between the 2 CLT assays, with hyperfibrinolytic and hypofibrinolytic profiles identified at the same time points during and after surgery. Severe hypofibrinolysis was less commonly reported in the Aarhus assay (36/319 samples; 11%) than in the Groningen assay (55/319 samples; 17%). No clot formation was observed in 31 of 319 samples in the Aarhus assay vs 0 of 319 samples in the Groningen assay. Clotting times increased much more profoundly on the addition of all 3 anticoagulants in the Aarhus assay. Conclusions: Despite the differences in laboratory, protocol, reagents, operator, data processing, and analysis, overall conclusions on fibrinolytic capacity are similar between the 2 laboratories. With a higher concentration of tPA in the Aarhus assay, the test becomes less sensitive for the detection of hypofibrinolysis and is more sensitive to the addition of anticoagulants.
KW - blood coagulation tests
KW - comparative study
KW - fibrin clot lysis time
KW - fibrinolysis
KW - tissue plasminogen activator
U2 - 10.1016/j.rpth.2023.100043
DO - 10.1016/j.rpth.2023.100043
M3 - Article
AN - SCOPUS:85150306113
SN - 2475-0379
VL - 7
JO - Research and practice in thrombosis and haemostasis
JF - Research and practice in thrombosis and haemostasis
IS - 1
M1 - 100043
ER -