Death rate in a small air-lift loop reactor of vero cells grown on solid microcarriers and in macroporous microcarriers

D E Martens, E A Nollen, M Hardeveld, C A Velden-de Groot, C D Gooijer, E C Beuvery, J Tramper

    Onderzoeksoutput: ArticleAcademicpeer review

    5 Citaten (Scopus)

    Samenvatting

    The death rate of Vero cells grown on Cytodex-3 microcarrierswas studied as a function of the gas flow rate in a smallair-lift loop reactor. The death rate may be described byfirst-order death-rate kinetics. The first-order death-rateconstant as calculated from the decrease in viable cells, theincrease in dead cells and the increase in LDH activity islinear proportional to the gas flow rate, with a specifichypothetical killing volume in which all cells are killed ofabout 2.10(-3)m(3) liquid per m(3) of air bubbles.In addition, an experiment was conducted in the sameair-lift reactor with Vero cells grown inside porous Asahimicrocarriers. The specific hypothetical killing volumecalculated from this experiment has a value of 3.10(-4)m(3) liquid per m(3) of air bubbles, which shows thatthe porous microcarriers were at least in part able to protectthe cells against the detrimental hydrodynamic forcesgenerated by the bubbles.

    Originele taal-2English
    Pagina's (van-tot)61-75
    Aantal pagina's15
    TijdschriftCytotechnology
    Volume23
    Nummer van het tijdschrift1
    DOI's
    StatusPublished - jan.-1997

    Vingerafdruk

    Duik in de onderzoeksthema's van 'Death rate in a small air-lift loop reactor of vero cells grown on solid microcarriers and in macroporous microcarriers'. Samen vormen ze een unieke vingerafdruk.

    Citeer dit