TY - JOUR
T1 - Diagnostic value of transcranial doppler to predict delayed cerebral ischemia after aneurysmal subarachnoid hemorrhage
T2 - To predict delayed cerebral ischemia
AU - van der Harst, J Joep
AU - Elting, Jan Willem J
AU - Hijlkema, Johanna
AU - Veeger, Nic J G M
AU - van Donkelaar, Carlina E
AU - van Dijk, J Marc C
AU - Uyttenboogaart, Maarten
N1 - © 2024. The Author(s).
PY - 2024/12
Y1 - 2024/12
N2 - BACKGROUND: Transcranial Doppler (TCD) is a technique to assess blood flow velocity in the cerebral arteries. TCD is frequently used to monitor aneurysmal subarachnoid hemorrhage (aSAH) patients. This study compares TCD-criteria for vasospasm and its association with Delayed Cerebral Ischemia (DCI). An overall score based on flow velocities of various intracranial arteries was developed and evaluated.METHODS: A retrospective diagnostic accuracy study was conducted between 1998 and 2017 with 621 patients included. Mean flow velocity (MFV) of the cerebral artery was measured between 2-5 days and between 6-9 days after ictus. Cutoff values from the literature, new cutoff values, and a new composite score (Combined Severity Score) were used to predict DCI. Sensitivity, specificity, and area under the curve (AUC) were determined, and logistic regression analysis was performed.RESULTS: The Combined Severity Score showed an AUC 0.64 (95%CI 0.56-.71) at days 2-5, with sensitivity 0.53 and specificity 0.74. The Combined Severity Score had an adjusted Odds Ratio of 3.41 (95CI 1.86-6.32) for DCI. MCA-measurements yielded the highest AUC to detect DCI at day 2-5: AUC 0.65 (95%CI 0.58-0.73). Optimal cutoff MFV of 83 cm/s for MCA resulted in sensitivity 0.73 and specificity 0.50 at days 2-5.CONCLUSION: TCD-monitoring of aSAH patients may be a valuable strategy for DCI risk stratification. Lower cutoff values can be used in the early phase after the ictus (day 2-5) than are commonly used now. The Combined Severity Score incorporating all major cerebral arteries may provide a meaningful contribution to interpreting TCD measurements.
AB - BACKGROUND: Transcranial Doppler (TCD) is a technique to assess blood flow velocity in the cerebral arteries. TCD is frequently used to monitor aneurysmal subarachnoid hemorrhage (aSAH) patients. This study compares TCD-criteria for vasospasm and its association with Delayed Cerebral Ischemia (DCI). An overall score based on flow velocities of various intracranial arteries was developed and evaluated.METHODS: A retrospective diagnostic accuracy study was conducted between 1998 and 2017 with 621 patients included. Mean flow velocity (MFV) of the cerebral artery was measured between 2-5 days and between 6-9 days after ictus. Cutoff values from the literature, new cutoff values, and a new composite score (Combined Severity Score) were used to predict DCI. Sensitivity, specificity, and area under the curve (AUC) were determined, and logistic regression analysis was performed.RESULTS: The Combined Severity Score showed an AUC 0.64 (95%CI 0.56-.71) at days 2-5, with sensitivity 0.53 and specificity 0.74. The Combined Severity Score had an adjusted Odds Ratio of 3.41 (95CI 1.86-6.32) for DCI. MCA-measurements yielded the highest AUC to detect DCI at day 2-5: AUC 0.65 (95%CI 0.58-0.73). Optimal cutoff MFV of 83 cm/s for MCA resulted in sensitivity 0.73 and specificity 0.50 at days 2-5.CONCLUSION: TCD-monitoring of aSAH patients may be a valuable strategy for DCI risk stratification. Lower cutoff values can be used in the early phase after the ictus (day 2-5) than are commonly used now. The Combined Severity Score incorporating all major cerebral arteries may provide a meaningful contribution to interpreting TCD measurements.
KW - Humans
KW - Subarachnoid Hemorrhage/diagnostic imaging
KW - Ultrasonography, Doppler, Transcranial/methods
KW - Female
KW - Male
KW - Middle Aged
KW - Retrospective Studies
KW - Brain Ischemia/diagnostic imaging
KW - Aged
KW - Adult
KW - Blood Flow Velocity/physiology
KW - Predictive Value of Tests
KW - Cerebrovascular Circulation/physiology
KW - Vasospasm, Intracranial/diagnostic imaging
KW - Sensitivity and Specificity
U2 - 10.1007/s00701-024-06164-1
DO - 10.1007/s00701-024-06164-1
M3 - Article
C2 - 38949680
SN - 0001-6268
VL - 166
JO - Acta Neurochirurgica
JF - Acta Neurochirurgica
M1 - 278
ER -