TY - JOUR
T1 - Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA?
AU - Meijer, Marrigje F
AU - Boerboom, Alexander L
AU - Bulstra, Sjoerd K
AU - Reininga, Inge H F
AU - Stevens, Martin
PY - 2017/9
Y1 - 2017/9
N2 - PURPOSE: Objective of this study was to compare intraoperative computer-assisted surgery (CAS) alignment measurements during total knee arthroplasty (TKA) with pre- and postoperative coronal alignment measurements using EOS 3D reconstructions.METHODS: In a prospective study, 56 TKAs using imageless CAS were performed and coronal alignment measurements were recorded twice: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D reconstructions. Thanks to the EOS radiostereography system, measurement errors due to malpositioning and deformity during acquisition are eliminated. CAS measurements were compared with EOS 3D reconstructions. Varus/valgus angle (VV), mechanical lateral distal femoral angle (mLDFA) and mechanical medial proximal tibial angle (mMPTA) were measured.RESULTS: Significantly different VV angles were measured pre- and postoperatively with CAS compared to EOS. For preoperative measurements, mLDFA did not differ significantly, but a significantly larger mMPTA in valgus was measured with CAS.CONCLUSION: Results of this study indicate that differences in alignment measurements between CAS measurements and pre- and postoperative EOS 3D are due mainly to the difference between weight-bearing and non-weight-bearing position and potential errors in validity and reliability of the CAS system. EOS 3D measurements overestimate VV angle in lower limbs with substantial mechanical axis deviation. For lower limbs with minor mechanical axis deviation as well as for mMPTA measurements, CAS measures more valgus than EOS. Eventually the results of this study are of clinical relevance, since it raises concerns regarding the validity and reliability of CAS systems in TKA.LEVEL OF EVIDENCE: IIb.
AB - PURPOSE: Objective of this study was to compare intraoperative computer-assisted surgery (CAS) alignment measurements during total knee arthroplasty (TKA) with pre- and postoperative coronal alignment measurements using EOS 3D reconstructions.METHODS: In a prospective study, 56 TKAs using imageless CAS were performed and coronal alignment measurements were recorded twice: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D reconstructions. Thanks to the EOS radiostereography system, measurement errors due to malpositioning and deformity during acquisition are eliminated. CAS measurements were compared with EOS 3D reconstructions. Varus/valgus angle (VV), mechanical lateral distal femoral angle (mLDFA) and mechanical medial proximal tibial angle (mMPTA) were measured.RESULTS: Significantly different VV angles were measured pre- and postoperatively with CAS compared to EOS. For preoperative measurements, mLDFA did not differ significantly, but a significantly larger mMPTA in valgus was measured with CAS.CONCLUSION: Results of this study indicate that differences in alignment measurements between CAS measurements and pre- and postoperative EOS 3D are due mainly to the difference between weight-bearing and non-weight-bearing position and potential errors in validity and reliability of the CAS system. EOS 3D measurements overestimate VV angle in lower limbs with substantial mechanical axis deviation. For lower limbs with minor mechanical axis deviation as well as for mMPTA measurements, CAS measures more valgus than EOS. Eventually the results of this study are of clinical relevance, since it raises concerns regarding the validity and reliability of CAS systems in TKA.LEVEL OF EVIDENCE: IIb.
KW - Computer-assisted surgery
KW - CAS
KW - Computer navigation
KW - Total knee arthroplasty
KW - Long-leg radiograph
KW - Coronal alignment
KW - Total knee replacement
KW - TKA
KW - TKR
KW - TOTAL KNEE ARTHROPLASTY
KW - LOWER-LIMB ALIGNMENT
KW - COMPUTER-ASSISTED NAVIGATION
KW - CORONAL ALIGNMENT
KW - CONVENTIONAL TECHNIQUE
KW - INTRAOBSERVER ERRORS
KW - REGISTRATION PROCESS
KW - LEG RADIOGRAPH
KW - REPLACEMENT
KW - ROTATION
U2 - 10.1007/s00167-016-4031-3
DO - 10.1007/s00167-016-4031-3
M3 - Article
C2 - 26913857
SN - 0942-2056
VL - 25
SP - 2894
EP - 2903
JO - Knee Surgery, Sports Traumatology, Arthroscopy
JF - Knee Surgery, Sports Traumatology, Arthroscopy
IS - 9
ER -