Dynamics of inner ear pressure release, measured with a double-barreled micropipette in the guinea pig

HP Wit*, EO Thalen, FWJ Albers

*Corresponding author voor dit werk

OnderzoeksoutputAcademicpeer review

27 Citaten (Scopus)

Samenvatting

The inner ear, fluid pressure was measured in scala media of the guinea pig through one barrel of a double-barreled micropipette after a sudden volume increase or decrease, caused by injection or withdrawal of artificial endolymph through the other barrel. During injection or withdrawal, the inner ear pressure changed in the order of 1-10 cm water, but it returned to its initial value within a few seconds. The time constant for the pressure recovery depended on the flow direction. It was on average 1.1 s after a short overpressure and 2.8 s after underpressure. The obtained results could be fitted with a simple physical model, when it was assumed that inner ear pressure recovery is a non-linear process, governed by a pressure-dependent flow resistance and/or membrane compliance. (C) 1999 Elsevier Science B.V. All rights reserved.

Originele taal-2English
Pagina's (van-tot)131-139
Aantal pagina's9
TijdschriftHearing Research
Volume132
Nummer van het tijdschrift1-2
StatusPublished - jun.-1999

Vingerafdruk

Duik in de onderzoeksthema's van 'Dynamics of inner ear pressure release, measured with a double-barreled micropipette in the guinea pig'. Samen vormen ze een unieke vingerafdruk.

Citeer dit