Evaluation of lung anatomy versus volume reproducibility for scanned proton treatments under Active Breathing Control

Lydia A. den Otter, E Kaza, Roel G J Kierkels, M.O. Leach, D.J. Collins, J.A. Langendijk, Antje Knopf

    OnderzoeksoutputAcademic

    Samenvatting

    Purpose/Objective
    Proton therapy is a highly conformal way to treat cancer. For the treatment of moving targets, scanned proton therapy delivery is a challenge, as it is sensitive to motion. The use of breath hold mitigates motion effects. Due to the treatment delivery over several fractions with delivery times extending the feasible breath hold duration, high reproducibility of breath holds is required. Active Breathing Control (ABC) is used to perform breath holds with controlled volumes. We investigated whether the lung anatomy is as reproducible as lung volumes under ABC, to consider ABC for scanned proton treatments.

    Material/Methods
    For five representative volunteers (3 male, 2 female, age: 25-58, BMI: 19 – 29) MR imaging was performed during ABC at two separate fractions. The image voxel size was 0.7x0.7x3.0 mm3. Each fraction consisted of four subsequent breath holds, resulting in a total of eight MRIs per volunteer. The interval between fractions was 1-4 weeks, keeping the same positioning. The intra-fraction reproducibility of the lung anatomy during breath hold was investigated, by comparing the MRI of the first breath hold with the three other MRIs of the same session. The inter-fraction anatomical reproducibility was investigated by comparing the first breath hold MRI of the first session with the four MRIs during the second session. To avoid any influence of setup variation, first a global rigid image registration was performed. Then the lung volume was semi-automatically segmented to define a region of interest for the deformable image registration (DIR). DIR was performed using Mirada RTx v1.2 (Mirada Medical, Ltd.), with a DIR grid resolution of 3.5x2x3 mm3. The deformation vector fields were analyzed using MATLAB v2014b. Magnitudes of the deformation vectors were calculated and combined for all five volunteers. The lung volumes were divided into six segments, to analyze the anatomical displacements on a local level. A boxplot showing the intra- and inter-fraction displacements with a schematic view of the six segments can be seen in figure 1.

    Results
    The lung volumes for all breath holds varied by 2% within and 7% between fractions. Looking at all five volunteers, up to 2 mm median intra- and inter-fraction displacements were found for all lung segments. The anatomical reproducibility decreased towards the caudal regions. Inter-fraction displacements were larger than intra-fractional displacements. Maximum displacements (99.3% of the magnitude vectors) reached 6 mm intra-fractionally and did not exceed 7 mm inter-fractionally.

    Conclusion
    While the lung volume differences were insignificant, relevant anatomical displacements were found. Moreover, a trend of increased displacements over time could be seen. ABC mitigates motion to some extent. Nevertheless, the remaining reproducibility uncertainties need to be considered during scanned proton therapy treatments. As next step, we aim to include this knowledge in a model to estimate their dosimetric influence for scanning proton therapy.
    Originele taal-2English
    StatusPublished - jul.-2017
    EvenementWetenschappelijke kringdag klinisch fysici radiotherapie Nederland - University medical center Utrecht, Utrecht, Netherlands
    Duur: 14-jul.-201714-jul.-2017

    Conference

    ConferenceWetenschappelijke kringdag klinisch fysici radiotherapie Nederland
    Verkorte titelWetenschappelijke kringdag
    Land/RegioNetherlands
    StadUtrecht
    Periode14/07/201714/07/2017

    Vingerafdruk

    Duik in de onderzoeksthema's van 'Evaluation of lung anatomy versus volume reproducibility for scanned proton treatments under Active Breathing Control'. Samen vormen ze een unieke vingerafdruk.

    Citeer dit