Image quality of DWI at breast MRI depends on the amount of fibroglandular tissue: implications for unenhanced screening

Mirjam Wielema, Paul E Sijens, Ruud M Pijnappel, Geertruida H De Bock, Marcel Zorgdrager, Marius G J Kok, Eva Rainer, Raoul Varga, Paola Clauser, Matthijs Oudkerk, Monique D Dorrius, Pascal A T Baltzer*

*Corresponding author voor dit werk

OnderzoeksoutputAcademicpeer review

4 Citaten (Scopus)
38 Downloads (Pure)

Samenvatting

OBJECTIVES: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density.

METHODS: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D).

RESULTS: Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively).

CONCLUSIONS: Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts.

CLINICAL RELEVANCE STATEMENT: Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts.

KEY POINTS: • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.

Originele taal-2English
Pagina's (van-tot)4730–4737
Aantal pagina's8
TijdschriftEuropean Radiology
Volume34
Vroegere onlinedatum27-nov.-2023
DOI's
StatusPublished - 2024

Vingerafdruk

Duik in de onderzoeksthema's van 'Image quality of DWI at breast MRI depends on the amount of fibroglandular tissue: implications for unenhanced screening'. Samen vormen ze een unieke vingerafdruk.

Citeer dit