Multi-institutional Quantitative Evaluation and Clinical Validation of Smart Probabilistic Image Contouring Engine (SPICE) Autosegmentation of Target Structures and Normal Tissues on Computer Tomography Images in the Head and Neck, Thorax, Liver, and Male Pelvis Areas

Mingyao Zhu, Karl Bzdusek, Carsten Brink, Jesper Grau Eriksen, Olfred Hansen, Helle Anita Jensen, Hiram A. Gay, Wade Thorstad, Joachim Widder, Charlotte L. Brouwer, Roel J. H. M. Steenbakkers, Hubertus A. M. Vanhauten, Jeffrey Q. Cao, Gail McBrayne, Salil H. Patel, Donald M. Cannon, Nicholas Hardcastle, Wolfgang A. Tome, Matthias Guckenberg, Parag J. Parikh*

*Corresponding author voor dit werk

    OnderzoeksoutputAcademicpeer review

    30 Citaten (Scopus)

    Samenvatting

    Purpose: Clinical validation and quantitative evaluation of computed tomography (CT) image autosegmentation using Smart Probabilistic Image Contouring Engine (SPICE).

    Methods and Materials: CT images of 125 treated patients (32 head and neck [HN], 40 thorax, 23 liver, and 30 prostate) in 7 independent institutions were autosegmented using SPICE and computational times were recorded. The number of structures autocontoured were 25 for the HN, 7 for the thorax, 3 for the liver, and 6 for the male pelvis regions. Using the clinical contours as reference, autocontours of 22 selected structures were quantitatively evaluated using Dice Similarity Coefficient (DSC) and Mean Slice-wise Hausdorff Distance (MSHD). All 40 autocontours were evaluated by a radiation oncologist from the institution that treated the patients.

    Results: The mean computational times to autosegment all the structures using SPICE were 3.1 to 11.1 minutes per patient. For the HN region, the mean DSC was > 0.70 for all evaluated structures, and the MSHD ranged from 3.2 to 10.0 mm. For the thorax region, the mean DSC was 0.95 for the lungs and 0.90 for the heart, and the MSHD ranged from 2.8 to 12.8 mm. For the liver region, the mean DSC was > 0.92 for all structures, and the MSHD ranged from 5.2 to 15.9 mm. For the male pelvis region, the mean DSC was > 0.76 for all structures, and the MSHD ranged from 4.8 to 10.5 mm. Out of the 40 autocontoured structures reviews by experts, 25 were scored useful as autocontoured or with minor edits for at least 90% of the patients and 33 were scored useful autocontoured or with minor edits for at least 80% of the patients.

    Conclusions: Compared with manual contouring, autosegmentation using SPICE for the HN, thorax, liver, and male pelvis regions is efficient and shows significant promise for clinical utility. (C) 2013 Elsevier Inc.

    Originele taal-2English
    Pagina's (van-tot)809-816
    Aantal pagina's8
    TijdschriftInternational Journal of Radiation Oncology Biology Physics
    Volume87
    Nummer van het tijdschrift4
    DOI's
    StatusPublished - 15-nov.-2013

    Vingerafdruk

    Duik in de onderzoeksthema's van 'Multi-institutional Quantitative Evaluation and Clinical Validation of Smart Probabilistic Image Contouring Engine (SPICE) Autosegmentation of Target Structures and Normal Tissues on Computer Tomography Images in the Head and Neck, Thorax, Liver, and Male Pelvis Areas'. Samen vormen ze een unieke vingerafdruk.

    Citeer dit