TY - JOUR
T1 - Multiple surface properties of worn RGP lenses and adhesion of Pseudomonas aeruginosa
AU - Bruinsma, Gerda
AU - Rustema-Abbing, M
AU - de Vries, Jacob
AU - Busscher, HJ
AU - van der Linden, M.L.
AU - Hooymans, JMM
AU - van der Mei, HC
PY - 2003/4
Y1 - 2003/4
N2 - The aim of this study is to determine rigid gas permeable (RGP) lens surface properties prior to and after wear that are influential on adhesion of Pseudomonas aeruginosa. After 10 and 50 days of wear and after end-stage use, lenses were collected for determination of physico-chemical surface properties and bacterial adhesion in a parallel plate flow chamber. Water contact angles on unused RGP lenses amounted 47 +/- 13degrees and were affected by wear. In addition, %O at the lens surfaces, as determined by X-ray photoelectron spectroscopy increased after use for 10 and 50 days, but decreased after end-stage wear. The %N hardly increased after wear and, in line, SDS-PAGE did not indicate adsorbed proteins. The surface roughness of the lenses, as measured by atomic force microscopy amounted 9nm after 10 and 50 days of use, but end-stage lenses were significantly rougher (48 +/- 23 nm). Moreover, initial deposition of P. aeruginosa #3 increased with increasing roughness for end-stage lenses. Multiple regression analysis, however, revealed that both physical and chemical surface properties were predictive for initial bacterial deposition to lens surfaces. After 10 days of wear, bacterial deposition was governed by the water contact angle, surface roughness, %O, %N, and %Si, while after 50 days of wear the surface roughness, %N, and %Si were found predictive for bacterial deposition. Initial bacterial deposition to end-stage lenses was solely dependent on the surface roughness. Summarizing, physico-chemical surface properties of RGP lenses change slightly during the first 10-50 days of wear, but end-stage lenses all had increased surface roughness, concurrent with increased bacterial adhesion. (C) 2002 Elsevier Science Ltd. All rights reserved.
AB - The aim of this study is to determine rigid gas permeable (RGP) lens surface properties prior to and after wear that are influential on adhesion of Pseudomonas aeruginosa. After 10 and 50 days of wear and after end-stage use, lenses were collected for determination of physico-chemical surface properties and bacterial adhesion in a parallel plate flow chamber. Water contact angles on unused RGP lenses amounted 47 +/- 13degrees and were affected by wear. In addition, %O at the lens surfaces, as determined by X-ray photoelectron spectroscopy increased after use for 10 and 50 days, but decreased after end-stage wear. The %N hardly increased after wear and, in line, SDS-PAGE did not indicate adsorbed proteins. The surface roughness of the lenses, as measured by atomic force microscopy amounted 9nm after 10 and 50 days of use, but end-stage lenses were significantly rougher (48 +/- 23 nm). Moreover, initial deposition of P. aeruginosa #3 increased with increasing roughness for end-stage lenses. Multiple regression analysis, however, revealed that both physical and chemical surface properties were predictive for initial bacterial deposition to lens surfaces. After 10 days of wear, bacterial deposition was governed by the water contact angle, surface roughness, %O, %N, and %Si, while after 50 days of wear the surface roughness, %N, and %Si were found predictive for bacterial deposition. Initial bacterial deposition to end-stage lenses was solely dependent on the surface roughness. Summarizing, physico-chemical surface properties of RGP lenses change slightly during the first 10-50 days of wear, but end-stage lenses all had increased surface roughness, concurrent with increased bacterial adhesion. (C) 2002 Elsevier Science Ltd. All rights reserved.
KW - adhesion
KW - Pseudomonas aeruginosa
KW - contact lens
KW - wear
KW - keratitis
KW - CONTACT-LENSES
KW - MICROBIAL KERATITIS
U2 - 10.1016/S0142-9612(02)00542-2
DO - 10.1016/S0142-9612(02)00542-2
M3 - Article
SN - 0142-9612
VL - 24
SP - 1663
EP - 1670
JO - Biomaterials
JF - Biomaterials
IS - 9
M1 - PII S0142-9612(02)00542-2
ER -