Pharmacokinetic Factors Associated With Early Meropenem Target Attainment in Pediatric Severe Sepsis

Kelli Paice*, Sonya Tang Girdwood, Tomoyuki Mizuno, Kathryn Pavia, Nieko Punt, Peter Tang, Min Dong, Calise Curry, Rhonda Jones, Abigayle Gibson, Alexander A. Vinks, Jennifer Kaplan

*Corresponding author voor dit werk

    Onderzoeksoutput: Review articlepeer review

    5 Citaten (Scopus)
    10 Downloads (Pure)

    Samenvatting

    OBJECTIVES: To determine the frequency of early meropenem concentration target attainment (TA) in critically ill children with severe sepsis; to explore clinical, therapeutic, and pharmacokinetic factors associated with TA; and to assess how fluid resuscitation and volume status relate to early TA.

    DESIGN: Retrospective analysis of prospective observational cohort study.

    SETTING: PICU in a single academic quaternary care children’s hospital.

    PATIENTS: Twenty-nine patients starting meropenem for severe sepsis (characterized as need for positive pressure ventilation, vasopressors, or ≥ 40mL/kg bolused fluid), of which 17 were newly escalated to PICU level care.

    INTERVENTIONS: None.

    MEASUREMENTS AND MAIN RESULTS: Concentration-time profiles were analyzed using modeling software employing opportunistic sampling, Bayesian estimation, and a population pharmacokinetic model. Time above four times minimum inhibitory concentration (T > 4×MIC), using the susceptibility breakpoint of 1 µg/mL, was determined for each patient over the first 24 hours of meropenem therapy, as well as individual clearance and volume of distribution (Vd) estimates. Twenty-one of 29 patients met a target of 40%T > MIC 4 µg/mL. Reaching TA, vs. not, was associated with lower meropenem clearance. We failed to identify a difference in Vd or an association between the TA group and age, weight, creatinine-based estimated glomerular filtration rate (eGFR), or the amount of fluid administered. eGFR was, however, negatively correlated with overall T > MIC.

    CONCLUSIONS: Eight of 29 pediatric patients with early severe sepsis did not meet the selected TA threshold within the first 24 hours of meropenem therapy. Higher clearance was associated with failure to meet targets. Identifying patients likely to have higher meropenem clearance could help with dosing regimens.

    Originele taal-2English
    Pagina's (van-tot)1103-1116
    Aantal pagina's14
    TijdschriftPediatric critical care medicine
    Volume25
    Nummer van het tijdschrift12
    DOI's
    StatusPublished - dec.-2024

    Vingerafdruk

    Duik in de onderzoeksthema's van 'Pharmacokinetic Factors Associated With Early Meropenem Target Attainment in Pediatric Severe Sepsis'. Samen vormen ze een unieke vingerafdruk.

    Citeer dit