Proton detection with large-acceptance scintillator detection systems in electron-scattering environments

A Pellegrino*, MG van Beuzekom, EE van den Born, DL Groep, WHA Hesselink, E Jans, N Kalantar-Nayestanaki, WJ Kasdorp, J Kos, MN Kruszynska, JJ van Leeuwe, FA Mul, CJG Onderwater, HZ Peek, T Ploegmakers, A Poelman, R Starink, JJM Steijger, HJ Sturris, JA TemplonJL Visschers, R. van Wijk

*Corresponding author voor dit werk

    Onderzoeksoutput: ArticleAcademicpeer review

    12 Citaten (Scopus)

    Samenvatting

    Two highly segmented plastic-scintillator arrays have been developed for proton detection in electron scattering experiments. The detectors subtend solid angles of 225 and 550 msr and cover energy ranges of 50-225 and 25-165 MeV, respectively. The charge and arrival time of each photomultiplier signal are digitized by flash ADCs and temporarily stored in a dual-port memory. The readout parameters are computer controlled, tuned, and monitored. These detectors have been employed in (e, e'p) and (e, e'pp) experiments for proton emission angles greater than 30 degrees and for luminosities up to 10(36) nucleons cm(-2) s(-1). The singles counting rates in the scintillator elements of the first layers were about 0.5 x 10(6) particles s(-1) and the trigger rate 1 MHz. The measured resolution in the excitation energy and timing spectra are 2.7% and 0.7 ns, respectively. (C) 1999 Elsevier Science B.V. All rights reserved.

    Originele taal-2English
    Pagina's (van-tot)188-205
    Aantal pagina's18
    TijdschriftNuclear instruments & methods in physics research section a-Accelerators spectrometers detectors and associated equipment
    Volume437
    Nummer van het tijdschrift2-3
    StatusPublished - 21-nov.-1999