Semi-automated 18F-FDG PET segmentation methods for tumor volume determination in Non-Hodgkin lymphoma patients: a literature review, implementation and multi-threshold evaluation

Onderzoeksoutput: ArticleAcademicpeer review

5 Citaten (Scopus)
236 Downloads (Pure)

Samenvatting

In the treatment of Non-Hodgkin lymphoma (NHL), multiple therapeutic options are available. Improving outcome predictions are essential to optimize treatment. The metabolic active tumor volume (MATV) has shown to be a prognostic factor in NHL. It is usually retrieved using semi-automated thresholding methods based on standardized uptake values (SUV), calculated from 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) images. However, there is currently no consensus method for NHL. The aim of this study was to review literature on different segmentation methods used, and to evaluate selected methods by using an in house created software tool.

A software tool, MUltiple SUV Threshold (MUST)-segmenter was developed where tumor locations are identified by placing seed-points on the PET images, followed by subsequent region growing. Based on a literature review, 9 SUV thresholding methods were selected and MATVs were extracted. The MUST-segmenter was utilized in a cohort of 68 patients with NHL. Differences in MATVs were assessed with paired t-tests, and correlations and distributions figures.

High variability and significant differences between the MATVs based on different segmentation methods (p < 0.05) were observed in the NHL patients. Median MATVs ranged from 35 to 211 cc.

No consensus for determining MATV is available based on the literature. Using the MUST-segmenter with 9 selected SUV thresholding methods, we demonstrated a large and significant variation in MATVs. Identifying the most optimal segmentation method for patients with NHL is essential to further improve predictions of toxicity, response, and treatment outcomes, which can be facilitated by the MUST-segmenter.
Originele taal-2English
Pagina's (van-tot)1102-1114
Aantal pagina's13
TijdschriftComputational and Structural Biotechnology Journal
Volume21
DOI's
StatusPublished - 20-jan.-2023

Vingerafdruk

Duik in de onderzoeksthema's van 'Semi-automated 18F-FDG PET segmentation methods for tumor volume determination in Non-Hodgkin lymphoma patients: a literature review, implementation and multi-threshold evaluation'. Samen vormen ze een unieke vingerafdruk.

Citeer dit