TY - GEN
T1 - Statistical evaluation of PET motion correction methods using MR derived motion fields
AU - Polycarpou, Irene
AU - Tsoumpas, Charalampos
AU - Marsden, Paul K.
PY - 2011
Y1 - 2011
N2 - Although there have been various proposed methods for motion correction in PET, there is not sufficient evidence to answer which method is better in terms of image quality and quantification. This study aims to characterize the behavior of the two main motion correction methods in terms of convergence and image properties. During the first method, reconstruct-transform-average (RTA), independent reconstructions of each gate are transformed to a reference gate and averaged. In the second method, motion-compensated image reconstruction (MCIR), all data are used with the motion information within a single reconstruction. The two methods are studied based on the OSEM algorithm. In this investigation motion fields were obtained from real dynamic MR acquisitions and concurrent PET data were simulated from the dynamic MR images. The two motion correction approaches were assessed statistically. Results indicate that MCIR is successful in the recovery of the true values of all regions, whereas RTA has high bias due to the non-negativity constraints and interpolation errors during transformation. It has been demonstrated that whilst at low iterations (i.e. 46 sub-iterations) the two methods have similar noise characteristics; at high iterations MCIR has increased noise. Finally, for low iterations the two methods have marginally similar coefficient of variation (CoV) whereas for large number of iterations RTA has clearly better CoV than MCIR. This study indicates that MCIR may provide superior performance overall to RTA providing the noise can be minimized.
AB - Although there have been various proposed methods for motion correction in PET, there is not sufficient evidence to answer which method is better in terms of image quality and quantification. This study aims to characterize the behavior of the two main motion correction methods in terms of convergence and image properties. During the first method, reconstruct-transform-average (RTA), independent reconstructions of each gate are transformed to a reference gate and averaged. In the second method, motion-compensated image reconstruction (MCIR), all data are used with the motion information within a single reconstruction. The two methods are studied based on the OSEM algorithm. In this investigation motion fields were obtained from real dynamic MR acquisitions and concurrent PET data were simulated from the dynamic MR images. The two motion correction approaches were assessed statistically. Results indicate that MCIR is successful in the recovery of the true values of all regions, whereas RTA has high bias due to the non-negativity constraints and interpolation errors during transformation. It has been demonstrated that whilst at low iterations (i.e. 46 sub-iterations) the two methods have similar noise characteristics; at high iterations MCIR has increased noise. Finally, for low iterations the two methods have marginally similar coefficient of variation (CoV) whereas for large number of iterations RTA has clearly better CoV than MCIR. This study indicates that MCIR may provide superior performance overall to RTA providing the noise can be minimized.
U2 - 10.1109/NSSMIC.2011.6153672
DO - 10.1109/NSSMIC.2011.6153672
M3 - Conference contribution
AN - SCOPUS:84858654318
SN - 9781467301183
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 3579
EP - 3585
BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Y2 - 23 October 2011 through 29 October 2011
ER -