TY - JOUR
T1 - Target coverage and organs at risk dose in hypofractionated salvage radiotherapy after prostatectomy
AU - Staal, Floor H.E.
AU - Janssen, Jorinde
AU - Krishnapillai, Sajee
AU - Langendijk, Johannes A.
AU - Both, Stefan
AU - Brouwer, Charlotte L.
AU - Aluwini, Shafak
N1 - © 2024 The Authors. Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology.
PY - 2024/7
Y1 - 2024/7
N2 - Background and purpose: Introducing moderately hypofractionated salvage radiotherapy (SRT) following prostatectomy obligates investigation of its effects on clinical target volume (CTV) coverage and organ-at-risk (OAR) doses. This study assessed interfractional volume and dose changes in OARs and CTV in moderately hypofractionated SRT and evaluated the 8-mm planning target volume (PTV) margin. Materials and methods: Twenty patients from the PERYTON-trial were included; 10 received conventional SRT (35 × 2 Gy) and 10 hypofractionated SRT (20 × 3 Gy). OARs were delineated on 539 pre-treatment Cone Beam CT (CBCT) scans to compare interfractional OAR volume changes. CTVs for the hypofractionated group were delineated on 199 CBCTs. Dose distributions with 4 and 6 mm PTV margins were generated using voxel-wise minimum robustness evaluation of the original 8-mm PTV plan, and dose changes were assessed. Results: Median volume changes for bladder and rectum were −26 % and −10 %, respectively. OAR volume changes were not significantly different between the two treatment schedules. The 8-mm PTV margin ensured optimal coverage for prostate bed and vesicle bed CTV (V95 = 100 % in >97 % fractions). However, bladder V60 <25 % was not achieved in 5 % of fractions, and rectum V60 <5 % was unmet in 33 % of fractions. A 6-mm PTV margin resulted in CTV V95 = 100 % in 92 % of fractions for prostate bed, and in 86 % for vesicle bed CTV. Conclusions: Moderately hypofractionated SRT yielded comparable OAR volume changes to conventionally fractionated SRT. Interfractional changes remained acceptable with a PTV margin of 6 mm for prostate bed and 8 mm for vesicle bed.
AB - Background and purpose: Introducing moderately hypofractionated salvage radiotherapy (SRT) following prostatectomy obligates investigation of its effects on clinical target volume (CTV) coverage and organ-at-risk (OAR) doses. This study assessed interfractional volume and dose changes in OARs and CTV in moderately hypofractionated SRT and evaluated the 8-mm planning target volume (PTV) margin. Materials and methods: Twenty patients from the PERYTON-trial were included; 10 received conventional SRT (35 × 2 Gy) and 10 hypofractionated SRT (20 × 3 Gy). OARs were delineated on 539 pre-treatment Cone Beam CT (CBCT) scans to compare interfractional OAR volume changes. CTVs for the hypofractionated group were delineated on 199 CBCTs. Dose distributions with 4 and 6 mm PTV margins were generated using voxel-wise minimum robustness evaluation of the original 8-mm PTV plan, and dose changes were assessed. Results: Median volume changes for bladder and rectum were −26 % and −10 %, respectively. OAR volume changes were not significantly different between the two treatment schedules. The 8-mm PTV margin ensured optimal coverage for prostate bed and vesicle bed CTV (V95 = 100 % in >97 % fractions). However, bladder V60 <25 % was not achieved in 5 % of fractions, and rectum V60 <5 % was unmet in 33 % of fractions. A 6-mm PTV margin resulted in CTV V95 = 100 % in 92 % of fractions for prostate bed, and in 86 % for vesicle bed CTV. Conclusions: Moderately hypofractionated SRT yielded comparable OAR volume changes to conventionally fractionated SRT. Interfractional changes remained acceptable with a PTV margin of 6 mm for prostate bed and 8 mm for vesicle bed.
KW - Hypofractionation
KW - Interfractional OAR volume change
KW - PERYTON-trial
KW - Planning target volume margin
KW - Prostate bed
KW - Salvage radiotherapy
UR - http://www.scopus.com/inward/record.url?scp=85196541081&partnerID=8YFLogxK
U2 - 10.1016/j.phro.2024.100600
DO - 10.1016/j.phro.2024.100600
M3 - Article
C2 - 39022396
AN - SCOPUS:85196541081
SN - 2405-6316
VL - 31
JO - Physics and imaging in radiation oncology
JF - Physics and imaging in radiation oncology
M1 - 100600
ER -