TY - JOUR
T1 - White Blood Cell Scintigraphy for Fracture-Related Infection
T2 - Is Semiquantitative Analysis of Equivocal Scans Accurate?
AU - Bosch, Paul
AU - IJpma, Frank F. A.
AU - Govaert, Geertje A. M.
AU - Reininga, Inge H. F.
AU - de Vries, Jean-Paul P. M.
AU - Glaudemans, Andor W. J. M.
PY - 2021/12
Y1 - 2021/12
N2 - Purpose: White blood cell (WBC) scintigraphy is considered the gold-standard nuclear imaging technique for diagnosing fracture-related infection (FRI). Correct interpretation of WBC scans in FRI is important since a false positive or false negative diagnosis has major consequences for the patient in terms of clinical decision-making. The European Association of Nuclear Medicine (EANM) guideline for correct analysis and interpretation of WBC scans recommends semiquantitative analysis of visually equivocal scans. Therefore, this study aims to assess the diagnostic accuracy of semiquantitative analysis of visually equivocal WBC scans for diagnosing FRI. Methods: A retrospective single-center study was performed in consecutive patients who received WBC scintigraphy in the diagnostic work-up for FRI between February 2012 and January 2017. All the visually equivocal scans were analysed using semiquantitative analysis by comparing leukocyte uptake in the manually selected suspected infection focus with the contralateral bone marrow (L/R ratio). Cut-off points for a 'positive' scan result of >0%, >10% and >20% leukocyte increase between the early and late scans were used in separate analyses. The discriminative ability was quantified by calculating the sensitivity, specificity and diagnostic accuracy. Results: In total, 153 WBC scans were eligible for inclusion. After visual assessment of all the scans, 28 visually equivocal scans were included. Dichotomization of the ratios using the cut-off of >0% resulted in a sensitivity of 30%, a specificity of 45% and a diagnostic accuracy of 40%. The >10% cut-off point resulted in a sensitivity of 18%, a specificity of 82% and a diagnostic accuracy of 66%. The >20% cut-off point resulted in a sensitivity of 0%, a specificity of 89% and a diagnostic accuracy of 67%. Conclusion: Semiquantitative analysis of visually equivocal WBC scans is insufficient for correctly diagnosing FRI.
AB - Purpose: White blood cell (WBC) scintigraphy is considered the gold-standard nuclear imaging technique for diagnosing fracture-related infection (FRI). Correct interpretation of WBC scans in FRI is important since a false positive or false negative diagnosis has major consequences for the patient in terms of clinical decision-making. The European Association of Nuclear Medicine (EANM) guideline for correct analysis and interpretation of WBC scans recommends semiquantitative analysis of visually equivocal scans. Therefore, this study aims to assess the diagnostic accuracy of semiquantitative analysis of visually equivocal WBC scans for diagnosing FRI. Methods: A retrospective single-center study was performed in consecutive patients who received WBC scintigraphy in the diagnostic work-up for FRI between February 2012 and January 2017. All the visually equivocal scans were analysed using semiquantitative analysis by comparing leukocyte uptake in the manually selected suspected infection focus with the contralateral bone marrow (L/R ratio). Cut-off points for a 'positive' scan result of >0%, >10% and >20% leukocyte increase between the early and late scans were used in separate analyses. The discriminative ability was quantified by calculating the sensitivity, specificity and diagnostic accuracy. Results: In total, 153 WBC scans were eligible for inclusion. After visual assessment of all the scans, 28 visually equivocal scans were included. Dichotomization of the ratios using the cut-off of >0% resulted in a sensitivity of 30%, a specificity of 45% and a diagnostic accuracy of 40%. The >10% cut-off point resulted in a sensitivity of 18%, a specificity of 82% and a diagnostic accuracy of 66%. The >20% cut-off point resulted in a sensitivity of 0%, a specificity of 89% and a diagnostic accuracy of 67%. Conclusion: Semiquantitative analysis of visually equivocal WBC scans is insufficient for correctly diagnosing FRI.
KW - WBC scintigraphy
KW - fracture-related infection
KW - FRI
KW - semiquantitative analysis
KW - infection
KW - imaging
KW - DIAGNOSTIC-ACCURACY
KW - IMAGE ACQUISITION
KW - LEUKOCYTES
U2 - 10.3390/diagnostics11122227
DO - 10.3390/diagnostics11122227
M3 - Article
VL - 11
JO - Diagnostics
JF - Diagnostics
SN - 2075-4418
IS - 12
M1 - 2227
ER -